UNIVERSAL CABLES LIMITED

Date: 17th June 2016
1BS5308 Part1 Instrumentation Cable Polyethylene Insulated
BS5308 Part1 Instrumentation Cable Polyethylene InsulatedVDE Ref CodePVC Sheath VersionRE-2Y(St)Y (Overall Screen)RE-2Y(St)Y PiMF(Individual Screen+Overall Screen)RE-2Y(St)Y-SWA(Overall Screen+Steel Wire Armour)RE-2Y(St)Y PiMF-SWA(Individual Screen+Overall Screen+Steel Wire Armour)LSOH Sheath Version:RE-2Y(St)H (Overall Screen)RE-2Y(St)HPiMF(Individual Screen+Overall Screen)RE-2Y(St)-SWA(Overall Screen+Steel Wire Armour)RE-2Y(St)HPiMF-SWA(Individual Screen+Overall Screen+ Steel Wire ArmourConstructionConstruction:Annealed solid copper(Class 1),Website:http://www.ue-cable.com,stranded(Class2), or fiexible(Class 5) to BS5360 .Binder tape:A 23 micron p.e.t.p.tape applied with a minimum 50% overlap.Insulation:Polyethylene to BS 6234 Type 03.Collective screen:Aluminium/p.e.t.p.laminated tape applied with the metallic side down in electrical contact with a 0.5mm 2 tinned copper drain wire over the p.e.t.p.binder tape.Pair identification:a)Collectively screened cables:Colour coded in accordance with Colour Code Chart 1 on page3b)Individually screened pairs:One blue core and one black core in each pair.Pairs identified by numbered screen isolation tape.Outer protection:Type 1 Extruded flame retardant PVC sheath.Type 2 Extruded polyethylene bedding,alvanised steel wire armour,extruded flame retardant PVC sheath.Pair screens:Aluminium/p.e.t.p.Laminated tape applied with the metallic side down in electrical contact with a 0.5 mm 2 tinned copper drain wire.A 23 micron isolation tape is applied over the screening tape with a minimum 50% overlap.Minimum bending radius:Type 1: 8 x diameter.Type 2: 12xdiameter.Voltage rating:300 volt core to earth and 500 volt core to core at maximum temperature of 65?Temperature rating:During Operation:-40?+70?During Operation:-0?+50?These cables are not for direct connection to the public mains supplyElectrical characteristicsParameterNoteUnitConductor size0.5mm?(1/0.8mm)0.5mm?(16/0.2mm)0.75mm?(24/0.2mm)1.0mm?(1/1.13mm)1.5mm?(7/0.53mm)Conductor resistancemax.?/Km36.839.726.518.212.3Insulation resistancemax.G?xKm55555Mutual capacitance at 1 kH-One pair and two pair(Quad)cables with collective screen and all cables with individually screened pairs -Cables with only collective screen except one pair and two pair(Quad)max.pF/m1151151151151157575757575Capacitance unbalance at 1 kHzmax.pF/250m250250250250250Inductance/resistance ratio(L/R)max.?H/?2525252525Test voltage(Core:core)-V10001000100010001000(Core:core)V10001000100010001000Rated voltagemax.V300/500300/500300/500300/500300/500MULTIPAIR INSTRUMENTATION CABLES(UNARMOURED)TO BS 5308 PART 1-COLLECTIVELY SCREENEDConductorNumber of PairsNominal Overall Dia(mm)Approx Weight (kg/km)1/0.8mm(0.5mm? )15.7402(Quad)6.560511.01301014.42202018.83803022.454016/0.2mm(0.5mm? )16.4602(Quad)7.380512.52001016.63402021.75703026.379024/0.2mm(0.75mm? )16.7752(Quad)7.7100513.72501018.14502023.98003028.911301/1.13mm(1.0mm?)16.8852(Quad)7.8115513.72901017.85002023.89503028.413307/0.53mm(1.5mm? )17.71002(Quad)9.1150515.83601021.06702027.912303033.71720MULTIPAIR INSTRUMENTATION CABLES(UNARMOURED)?TO BS 5308 PART 1 TYPE 1-INDIVIDUAL PAIR AND COLLECTIVELY SCREENEDConductorNumber of PairsNominal Overall Dia(mm)Approx Weight (kg/km)1/0.8mm(0.5mm? )29.7100512.91901017.73202022.95703027.382016/0.2mm(0.5mm? )211.4160514.62501020.54802026.77803031.7110024/0.2mm(0.75mm? )212.2190515.72701021.85502028.59603033.713201/1.13mm(1.0mm? )212.2190515.62701022.04802029.29103034.813207/0.53mm(1.5mm? )213.7250517.84001025.28002033.814003040.02040MULTIPAIR INSTRUMENTATION CABLES (ARMOURED)TO BS 5308 PART 1 TYPE 2-COLLECTIVELY SCREENEDConductorNumber of PairsNominal Diaunder Armour(mm)Nominal Overall Dia(mm)Armour WireDia(mm)Approx Weight (kg/km)1/0.8mm(0.5mm? )15.310.10.92252(Quad)6.110.90.9250510.615.60.94301014.020.11.257302018.425.41.612003022.029.21.6150016/0.2mm(0.5mm?)14.510.80.92502(Quad)6.911.70.930059.917.30.95601016.222.31.259702022.328.51.616403032.933.31.6211024/0.2mm(0.75mm? )16.311.10.92802(Quad)7.312.30.9330513.319.21.257501017.724.71.612602023.530.71.618903028.536.91.624401/1.13mm(1.0mm? )16.411.20.92902(Quad)7.412.40.9345513.219.11.257901017.423.71.2513102023.330.61.620403028.035.61.626407/0.53mm(1.5mm?)17.312.30.93302(Quad)13.313.70.9420521.121.51.259401027.427.81.2510502027.535.11.624003027.841.91.63120MULTIPAIR INSTRUMENTATION CABLES(ARMOURED)TO BS 5308 PART1TYPE 2-INDIVIDUAL PAIR AND COLLECTIVELY SCREENEDConductorNumber of PairsNominal Diaunder Armour(mm)Nominal Overall Dia(mm)Armour WireDia(mm)Approx Weight (kg/km)1/0.8mm(0.5mm? )210.114.30.9411513.518.41.256861018.323.61.2510372023.529.71.616643027.934.31.6213616/0.2mm(0.5mm? )212.015.80.9460515.220.11.257601021.127.01.613002027.333.31.618703032.339.62.0262024/0.2mm(0.75mm? )212.816.80.9500516.221.11.259201022.628.61.616102029.837.02.024201/1.13mm(1.0mm?)212.817.00.9515516.221.31.259501022.628.81.616702029.837.22.025407/0.53mm(1.5mm? )214.719.51.25730518.424.51.611801026.532.31.618202028.041.32.03030COLOUR CODE CHART 1(For Multipair PE insulated Collective Screened Cables to BS 5308 Part1.)Two-pair unscreened cables are cabled in quad formation and colour coded in clockwise order of rotation,black,blue,green,brown.All other cables up to 50 pairs conform to the following coding:Pair No.'A' Wire'B' WirePair No.'A' Wire'B' Wire1BlackBlue26WhiteYellow2BlackGreen27RedYellow3BlueGreen28OrangeYellow4BlackBrown29BlackGrey5BlueBrown30BlueGrey6GreenBrown31GreenGrey7BlackWhite32BrownGrey8BlueWhite33WhiteGrey9GreenWhite34RedGrey10BrownWhite35OrangeGrey11BlackRed36YellowGrey12BlueRed37BlackViolet13GreenRed38BlueViolet14BrownRed39GreenViolet15WhiteRed40BrownViolet16BlackOrange41WhiteViolet17BlueOrange42RedViolet18GreenOrange43OrangeViolet19BrownOrange44YellowViolet20WhiteOrange45GreyViolet21RedOrange46BlackTurquoise22BlackYellow47BlueTurquoise23BlueYellow48GreenTurquoise24GreenYellow49BrownTurquoise25BrownYellow50WhiteTurquoiseORDERING OPTIONS:1) Conductor:Bare or Tinned Conductor2)Conductor Size:Solid or Stranded(to IEC 228 Class 2 or 5 or 6)SizeClass1Class2Class5Class60.5mm ?1/0.8mm7/0.3mm16/0.2mm28/0.15mm0.75mm ?7/0.43mm24/0.2mm42/0.15mm1.0mm ?1/1.13mm7/0.44mm32/0.2mm56/0.15mm1.5mm ?7/0.53mm30/0.25mm84/0.15mm2.5mm ?7/0.67mm50/0.25mm140/0.15mm3)Insulation:PE/XLPE/LSF/LSOH4)Screening:Aluminium Tape/Copper Braiding5)Cabling:Multicore/Multipair/Multitriple6)Bedding&Sheathing Material:PE/PVC/LSF/LSOH7)Armouring:Steel Tape Armouring/Steel Wire Armouring8)Fire Performance:IEC 332-1(For Flame Retardant PVC sheath)IEC 332-3C(For Flame Retardant PVC or LSOH sheath)IEC 1034 Part 1&2 (For LSOH sheath)IEC 754 Part 1&2 (5%-15% for LSF sheath & 0.5% for LSOH sheath)Oxygen Index(32%-40% depending on different LSOH compound )Temperature Index(250 ? to 300 ?,depending on different LSOH compound)2.BS5308 Part 2BS5308 Part2 Instrumentation Cable PVC InsulatedVDE Ref CodePVC Sheath VersionRE-Y(St)Y (Overall Screen)RE-Y(St)Y PiMF(Individual Screen+Overall Screen)RE-Y(St)Y-SWA(Overall Screen+Steel Wire Armour)RE-Y(St)Y PiMF-SWA(Individual Screen+Overall Screen+Steel Wire Armour)LSOH Sheath Version:RE-H (St)H(Overall Screen)RE-H(St)HPiMF(Individual Screen+Overall Screen)RE-H(St)-H-SWA(Overall Screen+Steel Wire Armour)RE-H(St)HPiMF-SWA(Individual Screen+Overall Screen+ Steel Wire ArmourConstructionConductorAnnealed solid copper(Class 1),stranded(Class2), or fiexible(Class 5) to BS5360.Core/Pair identificationMulticore cables:Up to 40 cores-yellow cores with black numbers 41-80 cores-black cores with black numbersMultipair cables:Colour coded in accordance with Colour Code Chart 2 on page 6Pair screensAluminium/p.e.t.p.Laminated tape applied with the metallic side down in electrical contact with a 0.5 mm 2 tinned copper drain wire.A 23 micron isolation tape is applied over the screening tape with a minimum 50% overlap.Voltage rating300 volt core to earth and 500 volt core to core at maximum temperature of 65 ?Binder tapeA 23 micron p.e.t.p.tape applied with the metallic side down in electrica contact with a 0.5 0.5mm 2 tinned copper drain wire over the p.e.t.p.binder tape.Collective screenAluminium/p.e.t.p.laminated tape applied with the metallic side down in electrical contact with a 0.5mm 2 tinned copper drain wire over the p.e.t.p.binder tape.Outer protectionType 1 Extruded flame retardant PVC sheath.Type 2 Extruded PVC Type TM1 ,galvanised steel wire armour,extruded flame retardant PVC sheath.Minimum bending radiusType 1 8 x diameter.Type 2 12xdiameter.Temperature ratingDuring Operation:-40 ?+70?During Installation:-0 ?+50?These cables are not for direct connection to the public mains supplyElectrical characteristicsParameterNoteUnitConductor size0.5mmsq(16/0.2mm)0.75mmsq(24/0.2mm)1.5mmsq(7/0.53mm)Conductor resistanceMulticoremax.?/Km392612.1Multipair39.726.512.3Insulation resistancemax.G?xKm252525Mutual capacitance at 1 kHMutual capacitance of the pairs or adjacent coresmax.pF/m250250250Capacitance between any core or screenmax.pF/250m450450450Inductance/resistance ratio(L/R)max.?H/?252540Test voltage(Core:core)-V100010001000(Core:core)V100010001000Rated voltagemax.V300/500300/500300/500MULTICORE INSTRUMENTATION CABLES (UNARMOURED)TO BS 5308 PART 2-COLLECTIVELY SCREENEDPart No.ConductorNumber of PairsNominal Overall Dia(mm)Approx Weight (kg/km)BS5308-PVC-MC-CS-16*0.2mm16/0.2mm(0.5mm? )26.46036.77247.38068.71101011.31762014.33104019.5568BS5308-PVC-MC-CS-24*0.2mm24/0.2mm(0.5mm? )26.77537.19047.710069.31381012.12202015.43884021.1710BS5308-PVC-MC-CS-7*0.53mm7/0.53mm(1.0mm? )27.710338.313549.1150611.12051014.13302018.15804024.01065MULTIPAIR INSTRUMENTATION CABLES (UNARMOURED) TO BS 5308PART 2 TYPE 1- COLLECTIVELY SCREENEDConductorNumber of PairsNominal Overall Dia(mm)Approx Weight (kg/km)16/0.2mm(0.5mm? )16.4602(Quad)7.380512.52001016.63402021.75703026.379024/0.2mm(0.75mm? )16.7752(Quad)7.7100513.72501018.14502023.98003028.911307/0.53mm(1.5mm? )17.71002(Quad)9.1150515.83601021.06702027.912303033.71720MULTICORE INSTRUMENTATION CABLES(ARMOURED)TO BS 5308 PART 2 TYPE 2-COLLECTIVELY SCREENEDConductorNumber of PairsNominal Diaunder Armour(mm)NominalOverall Dia(mm)Armour WireDia(mm)Approx Weight (kg/km)16/0.2mm(0.5mm?)26.010.80.925536.311.10.928046.911.70.930568.313.30.93601010.916.10.95102013.920.01.258604019.126.11.6144024/0.2mm(0.75mm?)26.311.10.928036.711.50.930547.312.30.933568.913.90.94001011.716.90.95652015.021.11.259504020.727.91.615907/0.53mm(1.5mm?)27.312.30.933037.912.90.938048.713.70.9420610.715.70.95401013.719.80.97502017.724.71.2512604023.631.01.62140MULTIPAIR INSTRUMENTATION CABLES(ARMOURED)TOBS 5308 PART2TYPE 2- COLLECTIVELY SCREENEDConductorNumber of PairsNominal Diaunder Armour(mm)NominalOverall Dia(mm)Armour WireDia(mm)Approx Weight (kg/km)16/0.2mm(0.5mm?)16.06.010.82552(Quad)7.857.8511.7305512.112.117.36101016.216.222.310602022.622.628.518003026.426.433.3232024/0.2mm(0.75mm?)16.56.511.13052(Quad)7.47.412.3360517.317.319.28201017.717.724.713802023.023.030.720803029.729.736.926607/0.53mm(1.5mm?)17.512.30.93602(Quad)8.713.70.9460516.721.51.2510401021.127.81.611602028.035.12.02630ORDERING OPTIONS:1) Conductor:Bare or Tinned Conductor2)Conductor Size:Solid or Stranded(to IEC 228 Class 2 or 5 or 6)SizeClass1Class2Class5Class60.5mm?1/0.8mm7/0.3mm16/0.2mm28/0.15mm0.75mm?7/0.43mm24/0.2mm42/0.15mm1.0mm?1/1.13mm7/0.44mm32/0.2mm56/0.15mm1.5mm?7/0.53mm30/0.25mm84/0.15mm2.5mm?7/0.67mm50/0.25mm140/0.15mm3)Insulation:PE/XLPE/LSF/LSOH4)Screening:Aluminium Tape/Copper Braiding5)Cabling:Multicore/Multipair/Multitriple6)Bedding&Sheathing Material:PVC/LSF/LSOH7)Armouring:Steel Tape Armouring/Steel Wire Armouring8)Fire Performance:IEC 332-1(For Flame Retardant PVC sheath)IEC 332-3C(For Flame Retardant PVC or LSOH sheath)IEC 1034 Part 1&2 (For LSOH sheath)IEC 754 Part 1&2 (5%-15% for LSF sheath & 0.5% for LSOH sheath)Oxygen Index(32%-40% depending on different LSOH compound )Temperature Index(250 ? to 300 ?,depending on different LSOH compound)
Images
Latest News
Contact Information
Phone:
86-531-88817113
Fax:

86-531-88819113

Address:

1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China
Jinan, 250101

Website:

www.ue-cable.com

Contact Form