UNIVERSAL CABLES LIMITED

Date: 17th June 2016
300/500V XLPE Insulated, LSZH Sheathed, Screened Power Cables (2-4 Core)
300/500V XLPE Insulated LSZH sheathed Instrument cable (2-4cores) Application:The cables are mainly used in power stations,Website:http://www.ue-cable.com, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.Standard:Basic design to BS 5308FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING300/500VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder(if any): PP, Mylar tapeCircuit Protective Conductor: Annealed plain copper (class 2)Overall Screen: Aluminium/polyester tapeOuter Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90?C for XLPE250?C in short-circuit for 5s max.Minimum bending radius: 6 x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Overall Diameter ConductorNominal Insulation ThicknessCross- Section Area Of Circuit Protective ConductorNominal Sheath ThicknessNominal Overall DiameterMax.Dc Resistance Of Conductor @20?CApprox. WeightNoxmm2No./mmmmmmmm?mmmm?/kmkg/km2x1.07/0.441.320.61.00.98.118.1792x2.57/0.531.590.71.50.99.112.11022x2.57/0.672.010.82.51.010.57.411462x4.07/0.852.550.84.01.111.84.612053x1.07/0.441.320.61.00.98.618.1983x1.57/0.531.590.71.50.99.612.11293x2.57I0.672.010.82.51.011.17.411853x4.07I0.852.550.84.01.112.54.612624x1.07I0.441320.61.01.09.518.11234x1.57I0.531.590.71.51.010.612.11624x2.57I0.672.010.82.51.112.37.412334x4.07I0.852.550.84.01.213.94.61329Electrical PROPERTIESConductor Operating Temperature : ?90?CAmbient Temperature : ?30?CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.123456789101112mm2AAAAAAAAAAA1.5181722192523-----2.5242330263431-----4333040354641-----Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.53131272727272.51919161616164331210101010
Images
Latest News
Contact Information
Phone:
86-531-88817113
Fax:

86-531-88819113

Address:

1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China
Jinan, 250101

Website:

www.ue-cable.com

Contact Form