600/1000V LSZH Sheathed Screened (4cores)
600/1000V LSZH Sheathed Screened (4cores) Application:This cable is designed specifi cally to suit the broad spectrum of requirements of Variable Speed Drives and also include features for reducing the transmission of electromagnetic interference. ? ? ?This range of screened cables drastically reduce interferences from electrical noise,Website:http://www.ue-cable.com, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors. ? ? ?With shield conductivity of 1/10th of phase conductor conductivity, this range of VSD cables effectively restrain radiated and conducted radio-frequency emissions.Standard:Basic design to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000VCABLE CONSTRUCTION?Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.?Insulation: Extruded cross-linked XLPE compound.?Inner sheath1: LSZH Compound?Screen: Copper Tape?Inner sheath2: LSZH Compound?Armouring: Galvanised Steel Wire?Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIES?Temperature range during operation: Max.90?C for XLPE250?C in short-circuit for 5s max.?Minimum bending radius: 12 x Overall Diameter (for 1.5mm2 to 300mm2)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessDiameter Under ScreenDiameter Over Inner SheathArmour Wire DiameterNominal Overall DiameterApprox. Weightmm?No./mmmmmmmmmmmmmmkg/km4x1.57/0.530.71.89.712.113.917.76404x2.57/0.670.71.810.713.114.918.77304x47/0.850.71.812.014.416.220.08704x67/1.040.71.813.415.818.322.111804x107/1.350.71.815.618.020.524.314904x167/1.700.71.818.120.523.727.520704x257/2.140.91.822.324.127.331.127904x35(S)7/2.520.91.825.026.830.033.829404x50(S)19/1.781.02.027.829.632.837.03504x70(S)19/2.141.12.231.633.437.442.050004x95(S)19/2.521.12.335.437.241.246.063004x120(S)37/2.031.22.539.040.845.851.082004x150(S)37/2.251.42.642.043.848.854.296004x185(S)37/2.521.62.847.849.654.660.4115004x240(S)61/2.251.73.054.055.860.867.0144004x300(S)61/2.521.83.058.059.864.871.417200Note : Other conductor sizes & core confi gurations are available upon request.Electrical PROPERTIESConductor Operating Temperature : 90?C?Ambient Temperature : 30?CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm?AAAAAAAA1.527232925-23-282.536313933-30-36449425244-40-48662536656-50-601085739078-65-80161109411599115941401152514612415213114512518015035180154188132175150215180502191872281972101752552157027923829125126021531526595338289354304310260380315120392335410353355300430360150451386472406400335480405185515441539463455380540460240607520636546520440630530300698599732628590495700590Voltage Drop (Per Amp Per Meter)Conductor cross- sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single-phase a.c.3 or 4 cables, ?3-phase a.c.In ducts or in groundIn ducts or in ground123456mm?mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531.031.027.031.025.02.519.019.016.019.015.0412.012.010.012.09.767.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.1351.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.4000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.25000.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.190
Images
Latest News
Contact Information
Phone:
86-531-88817113
Fax:

86-531-88819113

Address:

1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China
Jinan, 250101

Website:

www.ue-cable.com

Contact Form