UNIVERSAL CABLES LIMITED

Date: 17th June 2016
XLPE Insulated, LSZH Sheathed, Overall Screened And Armoured Instrumentation Cables (Single Triple)
XLPE Insulated,Website:http://www.ue-cable.com, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2X(St)HSWAH 70?C / 300 VSTANDARDSBasic design to EN 50288-7APPLICATIONInstrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.FIRE PERFORMANCEFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)***EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil Resistance**ICEA S-73-532Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60?C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:Extruded cross-linked XLPE compound, EN 50290. 2-29.Pair:Two conductors twisted to form a pairLay-up:Pairs laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Inner sheath:HFFR compound, EN 50290-2-27Armour:Galvenized round steel wire, EN 10257-1Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30?C ? +70?CTemperature Range During Installation (Mobile State):-5?C ? +50?CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCableCodeRE-2X(St)HSWAHNo. of Triples x3xCross SectionNominal Insulation Thick- nessNominal Inner Sheath Thick- nessNominalOverall Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath Thick- nessNominal Overall DiameterApprox. WeightNo.x3xmm2mmmmmmmmmmmmkg/kmRE-2X(St)HSWAH 1T0.51x3x0.500.350.85.40.91.39.8200RE-2X(St)HSWAH 1T0.751x3x0.750.380.96.10.91.310.5220RE-2X(St)HSWAH 1T1.01x3x1.00.40.96.60.91.311.0244RE-2X(St)HSWAH 1T1.31x3x1.30.450.97.20.91.311.6268RE-2X(St)HSWAH 1T1.51x3x1.50.450.97.50.91.311.9293Note : Other conductor sizes & core configurations are available upon request.Electrical PROPERTIESConductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20?C)?/km36.72518.514.212.3Insulation resistance (20?C)M?.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)115Capacitance unbalance(1 kHz)pF/500 m (Max.)500InductancemH/km(Max.)1L / R (ratio) (max.)?H/?2525254040Operating voltage UrmsV300Test VoltageCore to CoreV1500Core to ScreenV1500
Images
Latest News
Contact Information
Phone:
86-531-88817113
Fax:

86-531-88819113

Address:

1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China
Jinan, 250101

Website:

www.ue-cable.com

Contact Form